🩺 УЗИ-сканеры и УЗИ-системы ✓ Экспертный аналитический обзор

Протоколы применения и клинические преимущества для врачей: Siemens Healthineers ACUSON Juniper

ACUSON Juniper Ultrasound System Datasheet

- No category advertisement Datasheet ACUSON Juniper Ultrasound System siemens.com/healthineers ACUSON Juniper Ultrasound System Table of Contents Introduction8 System Overview 9 System Architecture 9 User Interface 10 Dual-Option Keyboard 10 Ergonomics 10 Fully Articulated Flat Panel Display 10 Articulating Arm 11 Touch Screen 11 QuikStart Standby Mode 11 Audio Speakers 11 Physiological Interface 11 Operating System 11 Hard Drive 11 HIPAA Compliance 11 Transducer Technology 11 Transducer Ports 12 Transducer Storage and Gel Warmer 12 Transducer Technical Specifications 12 Imaging Modes and Options 14 Imaging Modes 14 2 siemens.com/ultrasound ACUSON Juniper Ultrasound System Display Modes 14 2D-mode Image Processing 14 MultiHertz Multiple Frequency Imaging 14 Tissue Harmonic Imaging (THI) 14 Focusing 14 2D Image Display 15 2D Calipers – Generic Measurements and Calculations 15 Color Doppler Velocity Imaging 15 Power Doppler Imaging/Directional Power Doppler 15 Color and Power Doppler Display 15 Pulsed Wave Spectral Doppler 16 Steerable Continuous Wave (SCW) Doppler 16 Spectral Doppler Display 16 Spectral Doppler Calipers – Generic Measurements and Calculations 16 M-mode 16 M-mode Image Display 16 M-mode Calipers – Generic Measurements and Calculations 16 User-defined Exams 17 Freeze, Cine and Cine Post-Processing Functions 17 Cine Review 17 Post-Processing Features in Freeze Frame or Cine 17 DTI Velocity (DTV) Capability 17 DTI Energy (DTE) Capability 17 siemens.com/ultrasound 3 ACUSON Juniper Ultrasound System Study Types 18 Exam-specific Measurements and Reports 18 Abdomen 18 Obstetrics 18 Gynecology 18 Echocardiography 19 Carotid 19 Aterial 19 Venous 19 Thyroid 19 Urology 19 Testicle 19 Pediatric Hip 19 TCD 19 Emergency Medicine 19 Penile 20 Digital Patient Study Storage and Archiving 20 Applications20 Enhanced Needle Visualization (Option) 20 eSieScan Workflow Protocols (Option) 20 syngo Arterial Health Package (AHP) (Option) 20 eSieTouch Elasticity Imaging (Option) 21 Liver Tissue Analysis 21 Virtual Touch Quantification (Option) 21 OB/Gyn Package 21 syngo Auto OB Measurements (Option) 21 syngo Auto Follicle Measurements (Option) 21 3-Scape Real-Time 3D Imaging 21 fourSight 4D Imaging (Option) 21 4 siemens.com/ultrasound ACUSON Juniper Ultrasound System Cardiac Imaging and Quantification Package 22 Cardiovascular 22 DTI Doppler Tissue Imaging (for Cardiac) 22 Physio Module (Option) 22 Stress Echo (Option) 22 eSieMeasure Workflow Acceleration Package (Option) 22 eSie Left Heart Measurement Package (Option) 23 Advanced Technologies and Features 23 Dynamic Persistence 23 Auto Flash Color Artifact Suppression 23 Dynamic TCE Technology 23 Advanced SieClear Spatial Compounding 23 Advanced SieClear Spatial Compounding in Color and Power Doppler 23 SieClear Multi-view Spatial Compounding 23 Clarify Vascular Enhancement (VE) Technology 23 SieScape Panoramic Imaging (Option) 23 eSieImage Multiparametric Optimization 24 syngo eSieCalcs Native Tracing Software 24 DICOM 3.0 Connectivity 24 DICOM Modality Worklist 24 DICOM MPPS – Modality Performed Procedure Step 24 DICOM Structured Reporting 24 Integrated Gel Warmer 24 Larger Gel Holder (Option) 24 QuikStart (Option) 24 Barcode Reader (Option) 25 Dual USB Foot Switch (Option) 25 Wireless Data Transfer 25 Protective Control Panel Cover (Option) 25 Ultrasound System Security – Virus Protection 25 siemens.com/ultrasound 5 ACUSON Juniper Ultrasound System Documentation Devices 25 Optional On-Board Video Devices 25 Digital Storage and Imaging Archiving 25 Image Capture 25 Storage Device 25 Read/Write DVD-R 25 USB 26 Display Out 26 Exam Restart 26 Exam Review 26 Siemens Remote Service (SRS) Support 26 System Dimensions 26 Electrical/Environmental Specifications 26 Integrating the Healthcare Enterprise (IHE) 27 Standards Compliance 27 Quality Standards 27 Design Standards 27 Acoustic Output Standards 27 6 siemens.com/ultrasound ACUSON Juniper Ultrasound System siemens.com/ultrasound 7 ACUSON Juniper Ultrasound System Introduction Everything you need and nothing you don’t Higher patient volumes. Larger patient sizes. Limited diagnostic certainty. In the face of these challenges, you need a reliable ultrasound system that can consistently deliver high-quality images across disease states – a system with optimized accessibility, expanded applications, and ease of use. The ACUSON Juniper was designed from the ground up to offer high-fidelity transmit and receive acoustic signals that greatly reduce noise and offer premium image quality and industry-leading elasticity solutions. ACUSON Juniper packs powerful capabilities into one of the industry’s smallest ultrasound systems. Able to fit in virtually any hospital room, ACUSON Juniper weighs an average of 27% less and is up to 36% smaller than other systems in its class. Image every patient Delivering high-quality care means being able to scan virtually every patient regardless of their size, weight or condition. With its wide variety of clinical solutions and fast image acquisition, ACUSON Juniper can improve diagnostic confidence across all departments, from radiology, interventional radiology, and urology to cardiovascular, orthopedic, and obstetrics/gynecological imaging. This clinical versatility combined with the industry-leading tissue elasticity imaging, ACUSON Juniper enables you to expand your ultrasound clinical and service offerings across virtually all patient and case types. Focus on what matters most This increased clinical performance comes at no cost to the functional design of the system. With ACUSON Juniper, you and your staff can move more easily between exams, patients, and spaces. Its 6 active ports, including 5 active transducer ports and 1 pencil port, support multiple clinical applications as you move about your day. Designed with intent, the system also adjusts to individual working preferences – pull the lightweight system from the front or back as you move between exams, tilt the monitor up or down as needed for your height, or rotate the control panel left or right depending on the patient bed location. Among the quietest ultrasound systems on the market, ACUSON Juniper creates a comfortable room environment and redefines adaptability, meeting staff preferences with ease so you can focus on what matters most – your patient. 8 siemens.com/ultrasound Where form meets function Small on the outside, yet big on the inside, ACUSON Juniper empowers you to image every patient, knowing you have the clinical information needed for confident decision making and a system designed to adapt to your everyday clinical and workflow needs. Abdominal Obstetrics Gynecology Small Parts Pediatric Neonatal Vascular Urology Echocardiography Musculoskeletal Intraoperative Abdominal Renal Bowel FAST Lung OB Early OB Fetal Echo OB (ADV) Gyn Pelvic floor Breast Testis Penile Thyroid Pediatric Hip TCD Emergency Medicine Penile 20 Digital Patient Study Storage and Archiving Applications20 Enhanced Needle Visualization (Option) 20 eSieScan Workflow Protocols (Option) 20 syngo Arterial Health Package (AHP) (Option) 20 eSieTouch Elasticity Imaging (Option) 21 Liver Tissue Analysis 21 Virtual Touch Quantification (Option) 21 OB/Gyn Package 21 syngo Auto OB Measurements (Option) 21 syngo Auto Follicle Measurements (Option) 21 3-Scape Real-Time 3D Imaging 21 fourSight 4D Imaging (Option) 21 4 siemens.com/ultrasound ACUSON Juniper Ultrasound System Lightweight maneuverability 21.5“ LED Monitor One of the easiest systems to maneuver, weighing only 76 kilos, and with both rear and front handles Highly adjustable for maximum operator adaptability Purposeful cable management Several hooks available for a clean, cable free environment 13.3” Touch display Smart UI for quicker scan settings and protocols Intuitive control panel Multiple transducer ports Customizable height, angle and keys Efficient workflow with 5 active transducer ports, 1 pencil probe and 2 physio ports Quiet, stress-free environment Every detail designed to maximize productivity Bedroom-like acoustic pressure 60% quieter than average Multiple storage bins available as well as space for easy installation of peripherals System Overview System Architecture Simple, intuitive user interface with home-base design minimizes repetitive hand motions and enables motor memory learning. All-digital signal processing and multibeam formation technology provide best-in-class imaging in all modes and enable seamless integration of features and options: • Parallel Quad beam processing of the RF signal data in the time and amplitude domains with new generation all digital beamformer technology – 2D-mode line density: Up to 512 lines – Processing channels: Up to 1032192 channels – Total system dynamic range: > 227 dB 110 mm • New front-end, beamformer and back-end engines for improved contrast resolution, plunkability, sensitivity and specificity • Floating control panel allows a wide range of adjustment for operator comfort in standing and sitting positions • Left/Right swivel articulation: ± 90º • Vertical articulation: 11 cm siemens.com/ultrasound 9 ACUSON Juniper Ultrasound System • System control panel illumination via Off/White/Blue (Not used/Available/Active) backlighting User Interface • Laser-optical trackball for higher sensitivity • On-screen text, control panel overlay and operating instructions are available in the following languages: – Chinese, English, French, Italian, German, Spanish • Digital and pull-out keyboard • Russian keyboard and operating instructions supported • Dynamic TCE™ Tissue Contrast Enhancement technology, Advanced SieClear™ spatial compounding, SieClear™ compounding and Clarify™ Vascular Enhancement (VE) technology are built into the ACUSON Juniper system to provide excellent image quality • Operating instructions are available in 27 languages • 13.3 inch touch screen (resolution 1920 × 1080) • Detect and prevent motion artifacts and reduce noise, simultaneously enhance color sensitivity with Dynamic Persistence proprietary technology and Auto Flash Color Artifact Suppression patent-pending technology • Enhance productivity through application-specific imaging presets, eSieImage tissue grayscale optimization technology Doppler auto optimization, enhanced measurement and report functionality, knowledge based workflow tools including syngo® Auto OB, Auto follcile measurements, eSie LH and standardized imaging protocols • Improve accuracy and reproducibility with the eSie Measure™ workflow acceleration package • Thumbnail menu provides on-screen thumbnail images and dynamic clips during exams • On-screen acoustic power indicator (AIUM/NEMA) output display standard Dual-Option Keyboard • Conventional Pull-out keyboard • Touch screen keyboard Ergonomics • Laser-optical trackball • Context sensitive: Dynamic back lighting • 5 active transducer ports • Intuitively organized user interface • Virtual touch quantification™ (VTQ) for personalized quantification of liver stiffness. This has been shown to help grade liver disease and may help physicians avoid liver biopsies in those patients that don’t need them • Vertical articulation: 11 cm • Streamline connectivity with solutions such as DICOM Print/Store, DICOM Modality Worklist, DICOM MPPS and DICOM structured reporting for OB/GYN, Vascular and Cardiac exams • Smart-intuitive body markers and pictograms • Left/Right swivel articulation: ± 90° • Ergonomic, tactile button designs • Smart-adaptive annotations • Robust selection for protocol • Tiltable touch screen with two USB ports • Increase functionality with fourSight™ 4D transducer technology, and integrated stress echo Fully Articulated Flat Panel Display • US security virus protection • 21.5“ full HD 1080P, flat panel liquid crystal display (LCD) with LED backlighting and wide-angle • Anatomical M mode (angle rotation and free hand drawing AMM) • High contrast ratio 1000 : 1 • Variable monitor positioning adjustment (height, swivel, tilt) – Range of height: (upright FPD) 163-141 cm (64.2-55.5 in) • Extended wide viewing angle: ± 89º • Folds down for transport – Minimum fold-down system height: 122 cm (48.0315 inch) • Default brightness: 170 cd/m² • Response time: 14 ms 10 siemens.com/ultrasound ACUSON Juniper Ultrasound System Articulating Arm HIPAA Compliance • Allows monitor transition for optimal ergonomic positioning toward, away and side-to-side The ACUSON Juniper ultrasound system provides the necessary tools to address the saving, accessibility and sharing of protocols according to HIPAA privacy safeguards. • Articulation independent of system and control panel Left/Right swivel articulation: ± 180º in either direction • Horizontal articulation Touch Screen • LCD (13.3”, 16 : 9) touch panel • Screen resolution: 1920 × 1080 • Dot pitch: 0.204 mm × 0.204 mm – USB 2.0 interface with host system • 2 USB ports • 16 : 9 aspect ratio QuikStart Standby Mode • QuikStart standby mode enhances system portability by reducing startup and shutdown times. – Fast system boot up: from off, approximately 90 seconds – Transport mode: from sleep mode to on, approximately 5 seconds – Transport mode lasts 30 minutes Audio Speakers • High-performance audio speakers integrated with control panel Physiological Interface • Standard 3-lead ECG interface • Auxiliary input/output for ECG and other physiology signals from third party devices • Continuous display in all real-time modes • Auto gain for physio signal • R-Wave single and dual trigger function • Respiratory trace • Heart rate display • Adjustable gain and trace position on-screen Transducer Technology The ACUSON Juniper system imaging transducers use Twin Cam – Zero Insertion Force connectors. This technology provides preserved signal integrity and improvement in signal to noise ratio. The ACUSON Juniper system supports a single crystal phased array transducer for instantaneous imaging. Ultra-sensitive, wideband transducers, matched with user-selectable MultiHertz™ multiple frequency imaging, improve resolution and penetration. Up to seven 2D and THI frequencies and up to three color Doppler and spectral Doppler frequencies expand the clinical versatility of a single transducer, thereby maximizing transducer investment. • Innovative ultra-low loss lens materials and microelectronic technologies for efficient performance and increased signal bandwidth • The following transducers are supported on the system: 5C1, 7C2, 16L4, 12L3, 11L4, 18H5, 5P1, 8V4, 10V4, 11M3, 8VC3, 9VE3, 10MC3, 9MC3, CW2/CW5 • 5P1 transducer single crystal array transducer technology for precise beam elevation control and exceptional spatial resolution throughout the field of view • 5 C1, 7C2 and 12L3 transducers utilize Hanafy lens transducer technology to provide excellent elevation focusing and uniform beam intensity throughout the field of view • 8 VC3 and 9VE3 transducers with fourSight 4D transducer technology provide superior image quality, contrast and detail resolution in 2D, 3D and 4D imaging modes • microCase™ transducer miniaturization technology and SuppleFlex™ transducer cables SuppleFlex cables and integrated cable management provide protection during exams and transport • Recovery time: less than 2 seconds • Advanced hybrid and disposable biopsy guides for specified transducers Operating System • Reusable and sterilizable stainless steel biopsy guides for 10MC3, 9MC3 and 9VE3 Supported with operating system Windows® 7 Hard Drive • Independent 2D and color frequencies for optimal resolution and penetration • Internal 500 GB Solid State Drive (SSD) • Allows storage of patient studies that include images, clips, reports and measurements • Image storage capacity up to 300,000 images with compression Note: Please refer to the dedicated transducer flyer on our website at siemens.com/ultrasound for more information. siemens.com/ultrasound 11 ACUSON Juniper Ultrasound System Transducer Ports Transducer Storage and Gel Warmer • Supports five active transducer ports • 7 transducer cup holders support all transducer designs and gel bottle storage • Twin Cam – Zero Insertion Force connector • Ergonomic cable management for in-exam convenience and secure transport • Electronic transducer selection • One-handed transducer connection and disconnection • Specialty transducer holders for endocavity, intraoperative, Aux CW, and 4D transducers • Ergonomic access to all transducer ports • Aux CW port for 2 MHz and 5 MHz CW transducers • Integrated gel warmer (standard) and large gel holder for Germany (optional) • Multiple cable hooks available throughout • Utility rear storage basket and magnetic side storage bin Transducer Technical Specifications Transducer 5C1 7C2 11M3 8VC3 9VE3 10MC3 9MC3 Array Type Curved Curved Curved Curved Curved Curved Curved Part Number 11268278 11268277 11284923 11284921 11284922 11268679 11284920 Frequency Bandwidth @ -20 dB 1.4-5.0 MHz 2.2-7.0 MHz 3.5-11.0 MHz 2.7-8.0 MHz 3.0-9.0 MHz 3.3-10.3 MHz 3.0-9.0 MHz Number of Elements 128 192 128 128 128 128 192 Footprint 60.8 mm 60.288 mm 27.136 mm 47.872 mm 25.5104 mm 27.392 mm 31.68 mm Maximum Field of View 70° 70° 110° 69° 145° 150° 220° Maximum Display Depth 300 mm 300 mm 140 mm 300 mm 140 mm 140 mm 140 mm Biopsy Guide Yes Yes NA NA Yes Yes Yes Exam Types Abdomen Renal Bowel FAST Lung OB Early OB OB (ADV) FetalEcho GYN Venous Arterial Pelvis Spine Abdomen Renal Bowel FAST Lung OB Early OB OB (ADV) FetalEcho GYN Spine Ped Abd Ped Echo Neo Echo Neo Head Abd OB Early OB OB (ADV) GYN Pelvic floor FetalEcho Early OB OB (ADV) OB GYN Pelvic floor Early OB OB OB (Adv) GYN Prostate Early OB OB OB (Adv) GYN Prostate 12 siemens.com/ultrasound Transducer 16L4 12L3 11L4 18H5 Array Type Linear Linear Linear Linear Part Number 11284846 11268279 11284844 11284924 Frequency Bandwidth @ -20 dB 4.3-15.4 MHz 2.9-11.5 MHz 3.6-13.0 MHz 4.5-18.0 MHz Number of Elements 192 192 128 192 Footprint 34.752 mm 51.264 mm 38.4 mm 26.88 mm Maximum Field of View 65 mm 133 mm 120 mm 68 mm Maximum Display Depth 60 mm 160 mm 160 mm 80 mm Biopsy Guide Yes Yes Yes NA Exam Types Bowel FAST Lung Breast Testis Penile Thyroid Ped Hip Carotid MSK Digital Nerve Bowel FAST Lung OB Breast Testis Penile Thyroid Ped Hip Carotid Venous Arterial Spine MSK Digital Nerve Bowel FAST Lung OB Breast Testis Penile Thyroid Ped Hip Carotid Venous Arterial Spine MSK Digital Nerve Testis Penile MSK Digital Nerve IOAbd Carotid Thyroid Transducer 5P1 8V4 10V4 CW2 CW5 Array Type Sector Vector Vector Non-Imaging Non-Imaging Part Number 11014154 11284847 11319697 246 252 Frequency Bandwidth @ -20 dB 1.1-4.8 MHz 2.7-8.0 MHz 4.1-9.9 MHz 2 MHz 5 MHz Number of Elements 96 64 128 2 2 Footprint 22.08 mm 9.6 mm 13.056 mm 17 mm 17 mm Maximum Field of View 90° 90° 90° NA NA Maximum Display Depth 300 mm 140 mm 140 mm NA NA Biopsy Guide NA NA NA NA NA Exam Types Abd FAST LUNG Renal Adult Echo Ped Echo TCD Ped Abd Ped Echo Neo Echo Neo Head Adult Echo Ped Echo Carotid TCD Ped Echo Imaging Modes and Options Imaging Modes • 2D – Fundamental 2D – Phase Inversion THI – Filtered THI • Color Doppler – Velocity-based color Doppler – Power Doppler – Directional power Doppler – Color Doppler tissue imaging • Spectral Doppler – Pulsed wave – Steerable Continuous Wave (SCW) – Auxiliary continuous wave on pencil probe – Spectral Doppler tissue imaging – Duplex and Triplex modes • M-mode – M-mode – Color M-mode – Anatomical M-mode Display Modes Selectable split screen display formats in 2D or 2D/color with M-mode and/or spectral Doppler mode: top-bottom or side-by-side in real-time and digital cine replay. • 4B-mode allowing simultaneous display of 4 static B-mode images • Virtual Format • Dual from freeze • Split/Zoom • Adjustable 2D or 2D/color 5 level image size Flexible combination of imaging modes in side-by-side Dual and Dual Select in real-time and digital cine replay. 2D-mode Image Processing • Fundamental frequency, transducer dependent: up to 4 • Harmonic frequency, transducer dependent: up to 5 • Adjustable size and position of field of view • Adjustable image size • Gain in one decibel increments: -30 dB to 30 dB Dynamic range in three decibel increments: 10 dB to 90 dB in 3 increments • Focal zones: up to 8 • Magnification: up to 10 • Acquired 2D-mode frame rates, depending on the transducer and imaging depth: up to 120 fps (frames per second) • CINE capture: up to 60 seconds • Resolution/speed: 6 levels • Persistence: 5 levels • Edge enhancement: 4 levels • Dynamic TCE (DTCE) technology for speckle reduction: 3 levels Gray maps: 7 and Color maps: 16 • SieClear and Advanced SieClear spatial compounding to reduce speckle and enhance contrast resolution • Tissue Harmonic Imaging (THI) technology to enhance visualization and reduce noise- eSieImage technology to optimize image brightness uniformity in the field of view by changing the DGC and overall gain • Clarify Vascular Enhancement (Clarify VE) technology to increase the contrast resolution and enhance the boundary detection: 7 levels • Custom Tissue Imaging (CTI) to optimize the 2D image by adjusting the speed of sound MultiHertz Multiple Frequency Imaging Siemens Healthineers’ unique MultiHertz multiple frequency imaging is designed to combine the resolution and penetration of several transducers into one. At the push of a button, the user can independently change frequencies for 2D, THI, color and spectral Doppler to select the optimal combination for image resolution, penetration and sensitivity. • Transmit frequencies: up to 9 user-selectable frequencies – 2D and M-mode: up to 4 fundamental frequencies – THI: up to 5 frequencies – Color Doppler and spectral Doppler: up to 3 frequencies – M-mode: up to 5 frequencies – SCW Doppler mode: 2 frequency – Auxiliary CW Doppler mode: 1 frequency Tissue Harmonic Imaging (THI) Selectable harmonic frequencies increase success with difficult-to-image patients, improving diagnostic confidence, and dramatically improving contrast and spatial resolution by reducing noise and clutter in the image. • MultiHertz imaging capability in THI • Available on the 7C2, 5C1, 11M3, 8VC3, 11L4, 12L3, 16L4, 18H5, 5P1, 8V4, 10V4, 9MC3, 10MC3, 9VE3 Focusing • Transmit focal zones: up to 8 zones • Digital dynamic receive focusing with dynamic apodization • Multi-position, user-selectable position • Can use multiple focal zones simultaneously 14 siemens.com/ultrasound ACUSON Juniper Ultrasound System 2D Image Display • Full screen, Split, Quad and Dual Select screen formats as well as Dual, Dual seamless, Dual select and Dual from Freeze • Color Doppler velocity maps: up to 10 user selectable maps (9 velocity and 1 velocity/variance) • Velocity scale range: ± 0.6 – ± 245.5 cm/sec (transducer dependent) • Curved Vector format • PRF scale range: 100 – 25500 Hz (transducer dependent) • L /R flip and U/D flip for all formats in real-time and digital cine replay • Gain: -20 – 20 dB in 1 dB increments • Split/Zoom • Wall filter: 4 selections • Image depth: 1 – 30 cm in 0.5 cm increments (transducer dependent) • Color smoothing: 4 levels • Tissue/color priority: 5 selections • Baseline Shift: 13 levels • Velocity tag • Digital read/write Zoom with image pan – Available on live and cine replay images – up to 10× zoom (transducer dependent) • 4B-mode • Adjustable display size: 5 level 2D Calipers – Generic Measurements and Calculations • Multiple cursor sets on frozen, live, dual screen and cine playback images • Distance measurements – Distance measurement – Depth measurement from skin line – Angle measurement – Area and circumference: ellipse, trace • Color Doppler line density: 6 selections • Tissue/color priority: 5 selections • Baseline Shift: 13 levels • Velocity tag • DTI™ Doppler Tissue Imaging capability available on the 5P1, 8V4, 10V4, 11M3 transducers Power Doppler Imaging/Directional Power Doppler • Available on all imaging array transducers • Multi-beam formation technology provides quad signal processing for power Doppler frame rates up to 66 fps (transducer dependent) • Left/right steer on all linear array transducers • Transmit frequencies: Up to 3 user-selectable frequencies per transducer • Power Doppler maps: Up to 16 maps (8 directional and 8 non-directional) • PRF scale range: 100 – 25500 Hz (transducer dependent) Color Doppler Velocity Imaging • Available on all imaging array transducers • Multi-beam formation technology provides quad signal processing for color Doppler frame rates up to 72 fps (transducer dependent) • Transmit frequencies: Up to 3 user-selectable frequencies per transducer • Gain: -20 – 20 dB in 1 dB increments • Power Doppler line density: 6 selections • Wall filter: 4 selections • Tissue/power Doppler priority: 5 selections • Color persistence: 5 levels Color and Power Doppler Display • 2D/C mode, Split 2D/2D/C mode • Dual real-time 2D/C mode • 2D/C/D mode (simultaneous, triplex), 2D/C/D mode • Left/right steer on all linear transducers • Color Doppler invert • Advanced processing in color Doppler mode resulting in excellent spatial resolution and superior Flash suppression • Auto Color flow state optimization with high, medium and low flow settings Pulsed Wave Spectral Doppler • Available on all imaging array transducers • Transmit frequencies: up to 3 user-selectable frequencies per transducer • DTI capability available on select transducers • Heart rate/Heart cycle/Time • Sweep speed: 10 selections • Post-processing gray maps: 7 maps • Doppler colorization maps: 12 user-selectable maps • Gain: -30 ~ 30 dB in 1 dB increments • PRF range: 152 – 39100 Hz (transducer dependent) • Velocity scale range: ± 1.0 – ± 840 cm/sec with 0° angle correction (transducer dependent) • Angle correction: 0 – 89° in 1° increments • Gate size: 0.5 – 20 mm • Wall filter: 14 – 6055 Hz, 7 steps (transducer dependent) • Baseline shift: 13 levels • Spectral invert • Autotrace function Steerable Continuous Wave (SCW) Doppler • Available on all phased array transducers • Transmit frequency up to 2 frequency • Sweep speed: 10 selections • Post-processing gray maps: 7 maps • Doppler colorization: 12 maps • Gain: -30 ~ 30 dB in 1 dB increments • PRF range: 152 ~ 52100 Hz sample rate (transducer dependent) • Velocity scale range: ± 1.5 – ± 1100 cm/sec with 0° angle correction (transducer dependent) • Wall filter: 14 – 6950 Hz, 7 steps (transducer dependent) • Baseline shift: 13 levels • Spectral invert • Auto trace function is supported in SCW mode Spectral Doppler Display • Full screen Doppler trace, 2D/Doppler mode, triplex or update 2D/C/Doppler • Imaging display: 4 formats – Top-bottom: 1/3-2/3, 1/2, 2/3-1/3 – Side-by-side: 50 – 50 Spectral Doppler Calipers – Generic Measurements and Calculations • Multiple cursor sets on frozen and cine playback images – Distance – Time – Slope – Heart rate M-mode • Available on all imaging array transducers • Anatomical M-mode – live and cineloop • Frequencies: Up to 4 user-selectable frequencies, including fundamental and harmonics • Edge enhancement: 4 selections • Display dynamic range: 10 – 90 dB in 3 dB increments • Gain: -30 – 30 dB in 1 dB increments • Gray maps: 7 maps • M-mode colorization maps: 16 maps • Sweep speed: 10 selections M-mode Image Display • Full screen M-mode, 2D/M-mode • Imaging display: 4 formats – Top-bottom: 1/3-2/3, 1/2-1/2, 2/3-1/3 – Side-by-side: 50 – 50 M-mode Calipers – Generic Measurements and Calculations • Multiple cursor sets on frozen and cine playback images – Distance – Time – Slope – Heart rate User-defined Exams • All imaging modes and parameters are customizable and programmable using QuickSet user-programmable system parameters • Up to 2 pages on touch screen exam • QuickSet parameters combine all preferred imaging mode parameters, annotation, text and measurements into a single user preset Freeze, Cine and Cine Post-Processing Functions Cine Review The cine feature is standard and offers the ability to review real-time acquired data. All real-time, post-acquisition optimization functions are available in cine review. • Frame-by-frame cineloop review and continuous cine motion review, including control of playback rate • Independent cine review in mixed modes (2D/M, 2D/Doppler, 2D/C/Doppler) • Independent cine review in 2D Dual Select mode with image align playback feature • Standard cine memory: up to 1260 frames • Acoustic clip capture from cine review Post-Processing Features in Freeze Frame or Cine • 2D-mode – Zoom/pan – Gray map – Colorization map – Measurements/reports/annotations/pictograms • Color Doppler – Zoom/pan – Color map – Color invert – Measurements/reports/annotations/pictograms • Spectral Doppler – Gain – Gray map – Doppler colorization map – Angle correct – Measurements/reports/annotations/pictograms • M-mode – Gray map – M-mode colorization map – Measurements/reports/annotations/pictograms DTI Velocity (DTV) Capability Provides real-time imaging display of tissue mean velocities in the sampling area within the user-selected region of interest using various user-selectable color coding maps. • Available in Cardiology imaging • Level: Independent signal gain adjustment DTI Energy (DTE) Capability Provides real-time imaging display of the intensity of Doppler signals returning from tissue within the userselected region of interest using various user-selectable color-coding maps. • Available on all probes which support cardiac application • Level: independent signal gain adjustment siemens.com/ultrasound 17 ACUSON Juniper Ultrasound System Study Types The ACUSON Juniper system is designed to support many multi-specialty imaging applications. Factory-supplied exam and transducer dependent imaging presets have been carefully optimized for each application to provide consistency, reliability and increased productivity. All applications include body markers, text and annotation labels. Selected applications support customized reports. The following study types are supported: • Abdominal • Renal • Bowel • FAST • Lung • Obstetrics • Gynecology • Pelvic floor Imaging • Small Parts (Breast, Testis, Penile, Thyroid) and superficial • Musculoskeletal (Spine, MSK, Digital, Nerve) • Echocardiography (Adult, Pediatric, Fetal and Neonatal) • Pediatric Imaging (Abdomen and Hip Joint) • Neonatal Imaging • Vascular (Carotid, Peripheral Artery & Vein, TCD) Abdomen • All general measurements and calculations Obstetrics • Early Obstetrics Gestational Age (GA) measurements are MSD, CRL, and Yolk Sac • Gestational Age parameter labels are MeanSac Diameter (MSD), CRL, BPD, OFD, HC, AC, TAD, APAD, FL, HL, Ulna (UL), Tibia (TL), Foot (FT), FTA and BinocD (BN) • Unlimited user-defined measurement labels • Calculations include: EFW from the selected reference, HC/AC, TCD/AC, LVW/HW, BPDa, FL/AC, FL/BPD, CI,AFI, A XT • Comprehensive Fetal Heart measurements and calculations Facial Angle – Nuchal Translucency and Nuchal Fold measurements • Calculations for both Gestational Age (GA) and Estimated Date of Confinement (EDC) • Early OB and Standard OB patient reports include worksheets for viewing the progress of the report and editing during the exam process • Multiple fetus reporting capabilities – Maximum of 4 • Growth Analysis Graphs with exam file linking • Detailed Fetal Heart report page • Stress Echo Gynecology • Urology (Pelvis, Prostate) • Micturated and residual volume calculation • Intra-Operative • Uterus, Right and Left Ovary, Right and Left Follicle, CRL, MSD, GS and Yolk Sac measurements Exam-specific Measurements and Reports • All measurement and report packages are available for use with all exam types. • All exam-specific measurement and reports support: – All general measurements and calculations – Comprehensive, customizable, patient reports and worksheets – Customizable anatomy descriptions – Physician summary utility – supports on-system report generation including customizable letterhead, patient data, results, graphs, images, comments, recommendations and a customizable signature line The following Measurements and Reports packages are available on the ACUSON Juniper ultrasound system: 18 siemens.com/ultrasound • Follicle measurement supports up to 15 follicles • Follicle measurement methods supported – MDistance – 2Dist + Avg – 3Dist + Avg – 2Dist Avg – 3Dist Avg – Area – Volume – Circumference ACUSON Juniper, CV Edition Ultrasound System - Siemens Healthineers ACUSON Juniper, CV Edition1, is a high-performance, cardiology system capable of performing a variety of clinical applications with minimal investments while offering great diagnostic confidence across all departments. - Home - Medical Imaging - Ultrasound Machines - Cardiovascular - ACUSON Juniper Ultrasound System, CV Edition ACUSON Juniper Ultrasound System, CV Edition When more is essential. Features & Benefits Routinely delivering high-quality care means scanning virtually every patient regardless of their size, weight, or condition. With its clinical versatility and industry-leading AI-powered2 measurements, the ACUSON Juniper, CV Edition, enables you to expand your ultrasound clinical and service offerings across virtually all patient and case types. B-mode High contrast resolution, complete image uniformity: full diagnostic quality. Color Improve diagnostic confidence with exceptional color resolution. Transducer Technology Siemens Healthineers Ultrasound offers a wide range of innovative transducers extending the diagnostic capabilities of your ultrasound system. The patented technologies of our advanced transducer design accommodate a broad range of examinations and applications, offering unparalleled clinical flexibility and value. - 5P1 Transducer Clinical Applications: Abd, FAST, LUNG, Renal, Adult Echo, Ped Echo, TCD 10V4 Transducer Clinical Applications: Ped Abd, Ped Echo, Neo Head, Neo Echo 8V4 Transducer Clinical Applications: Ped Abd, Ped Echo, Neo Head, Neo Echo 5VT Transducer Clinical Applications: Transesophageal Echocardiography - 6C1 Transducer Clinical Applications: Abdomen, Abd-Difficult, Renal, FAST, Obstetrics, Early OB, OB (ADV), Fetal Echo, Bowel, Lung, Spine, Gynecology, Pelvis, PV-Arterial, Venous 7C2 Transducer Clinical Applications: Abd, Renal, Bowel, FAST, Lung, OB, Early OB, OB (Adv), Fetal Echo, GYN, Pelvis, Ped Abd, Spine 5C1 Transducer Clinical Applications: Abd, Renal, Bowel, FAST, Lung, OB, Early OB, OB (Adv), Fetal Echo, GYN, Venous, Arterial, Pelvis, Spine 11M3 Transducer Clinical Applications: Ped Abd, Ped Echo, Neo Echo, Neo Head, Carotid 8VC3 Transducer Clinical Applications: Abd, OB, Early OB, OB (ADV), GYN, Pelvic floor, Fetal Echo - 14L4 Transducer Clinical Applications: Thyroid, Breast, MSK, FAST, C-Vascular, P-Vascular, Venous, Bowel, Lung, OB, Testis, Penile, PedHip, Spine, Digital, Nerve 11L4 Transducer Clinical Applications: Bowel, FAST, Lung, OB, Breast, Testis, Penile, Thyroid, Ped Hip, Carotid, Venous, Arterial, Spine, MSK, Digital, Nerve 12L3 Transducer Clinical Applications: Bowel, FAST, Lung, OB, Breast, Testis, Penile, Thyroid, Ped Hip, Carotid, Venous, Arterial, Spine, MSK, Digital, Nerve 13L4 Transducer Clinical Applications: Bowel, FAST, Lung, OB, Breast, Penile, Thyroid, Ped Hip, Carotid, Venous, Arterial, Spine, MSK, Digital, Nerve 16L4 Transducer Clinical Applications: Bowel, FAST, Lung, Breast, Testis, Penile, Thyroid, Ped Hip, Carotid, MSK, Digital, Nerve 18H5 Transducer Clinical Applications: Testis, Penile, MSK, Digital, Nerve, IO Abd, Carotid, Thyroid - 9MC3 Transducer Clinical Applications: Early OB, OB (Adv), GYN, Prostate, OB 9VE3 Transducer Clinical Applications: Early OB, OB (Adv), GYN, Pelvic floor, OB 10MC3 Transducer Clinical Applications: Early OB, OB (Adv), GYN, Prostate, OB - CW2 Transducer Clinical Applications: Adult Echo, Pediatric Echo CW5 Transducer Clinical Applications: Carotid, TCD, Pediatric Echo CW8 Transducer Clinical Applications: Carotid, Arterial Velocity Vector Imaging syngo® Velocity Vector Imaging technology supports assessment of global and regional myocardial muscle and motion mechanics including global longitudinal strain. Stress Echo The Stress Echo application provides tools for ECG-triggered acquisition, display, selection, comparison, evaluation and archiving of multiple cardiac loops during various stages of a Stress Echo examination. Arterial Health Package The syngo® Arterial Health Package (AHP) is a noninvasive method for evaluation of cardiovascular risk and provides an advanced quantification application to access arterial health. The ACUSON Juniper, CV Edition, helps to reduce operator variability, improves accuracy and gives greater consistency in reporting through several automated tools. Lightweight Manuverability The ACUSON Juniper, CV Edition, weighs an average of 27% less and is up to 36% smaller than other systems in its class. Five Active Transducer Ports and One CW Port The five active transducer ports and one CW port support nineteen transducers for a wide variety of scanning capability. Intuitive Control Panel and 13.3” Touch Display A smart UI for quicker scan settings and protocols, and customizable height, angle and keys. Adaptable to Any Environment Highly adjustable for maximum operator adaptability. AI-enabled Technologies* eSie Left Heart eSie Left Heart measurement package is a robust tool that enhances accuracy and workflow by automatically detecting left ventricular and atrial borders and generating measurements on typical adult transthoracic images. eSie Measure The eSie Measure workflow acceleration package provides semi-automated measurements for routine echo exams, improving efficiency and consistency for end users. Clinical Use View some of the clinical images from the ACUSON Juniper, CV Edition. Technical Specifications Customer Services Kinectus… Always connected. Always Advancing. Always ahead. Kinectus is a secure, easy-to-use, cloud-based remote service solution that keeps you connected and your software up to date, all while minimizing service costs and adhering to current security and compliance guidelines. teamplay Fleet teamplay Fleet enables you to streamline your Siemens Healthineers fleet management and to optimize your asset performance. Education & Training Digital education with Siemens Healthineers Academy Accelerate workflow and knowledge with Siemens Healthineers Academy and Siemens Healthineers Academy Admin1 . Engage in learning activities at any time and on any device for a personalized learning experience with Healthineers Academy. Using a Siemens Healthineers Academy Admin subscription, you can access a workforce education management plan as well as analytics and progress report tracking. 1 Subscription required. Availability of subscription depends on country. Did this information help you? Thank you. Software application leveraging machine learning-based Artificial Intelligence to achieve the intended outcome. AI-powered measurement tools consist of software applications leveraging machine learning-based Artificial Intelligence to achieve the intended outcome including eSie Measure and eSie Left Heart.

← Вернуться в раздел «УЗИ-сканеры и УЗИ-системы»